NICET II Fire Alarm Technician

ho-chunk· Government Contracts
Apply Now ↗
📍 Columbia, SC, USFULL TIME

About this role

Summary

NICET II Fire Alarm Technician

Location: Moncrief Army Health Clinic, Fort Jackson, South CarolinaPosition Type: Full-TimeStart Date: September 1, 2026Clearance/Access: Ability to obtain and maintain access to Fort JacksonCertification Required: NICET Level II – Fire Alarm Systems

Position Overview

We are seeking a qualified and dependable NICET II Fire Alarm Technician to support fire alarm system operations and maintenance at Moncrief Army Health Clinic (MAHC), Fort Jackson, South Carolina.

The technician will be responsible for the inspection, testing, maintenance, troubleshooting, repair, documentation, and upgrade of fire alarm and associated life-safety systems supporting a critical military healthcare facility.

The successful candidate will demonstrate strong technical knowledge, attention to detail, professional communication skills, and a commitment to maintaining reliable life-safety systems in accordance with applicable codes, standards, and installation requirements.

Essential Duties and Responsibilities

  • Perform scheduled and preventive maintenance of fire alarm and life-safety systems.
  • Conduct fire alarm inspections and testing in accordance with applicable requirements and approved procedures.
  • Troubleshoot fire alarm control panels, initiating devices, notification appliances, power supplies, modules, circuits, and related equipment.
  • Diagnose system faults and determine appropriate corrective actions.
  • Perform repairs, component replacement, programming, and system modifications as authorized.
  • Assist with fire alarm system installations, upgrades, alterations, and acceptance testing.
  • Read and interpret fire alarm drawings, wiring diagrams, equipment manuals, specifications, and system documentation.
  • Use appropriate electronic test equipment and diagnostic tools.
  • Maintain accurate inspection, testing, maintenance, repair, and service records.
  • Prepare detailed service reports documenting deficiencies, corrective actions, test results, and recommended repairs.
  • Identify system deficiencies and communicate recommended corrective actions to management and Government representatives.
  • Coordinate work activities with facility personnel and other contractors to minimize disruption to healthcare operations.
  • Respond to emergency service calls and system trouble conditions as required.
  • Maintain a clean, safe, and organized work environment.
  • Follow all applicable safety requirements, including OSHA, EM 385-1-1, installation safety procedures, and site-specific requirements.
  • Perform other related duties as assigned.

Required Qualifications

  • NICET Level II certification in Fire Alarm Systems.
  • High school diploma or equivalent.
  • Demonstrated experience working with commercial fire alarm systems.
  • Working knowledge of fire alarm system installation, inspection, testing, troubleshooting, and repair.
  • Ability to read and interpret fire alarm drawings, schematics, wiring diagrams, and technical manuals.
  • Familiarity with applicable NFPA fire alarm requirements, particularly NFPA 72.
  • Working knowledge of applicable OSHA and safety requirements.
  • Ability to use electrical and electronic test equipment.
  • Valid driver's license.
  • Ability to obtain and maintain required installation access credentials.
  • Ability to work independently and effectively as part of a team.
  • Strong written and verbal communication skills.

Preferred Qualifications

  • Three or more years of fire alarm service and maintenance experience.
  • Previous experience supporting Department of Defense, military, healthcare, or other critical facilities.
  • Experience with large-scale addressable fire alarm systems.
  • Experience with fire alarm system programming and configuration.
  • Familiarity with UFC requirements and Department of Defense fire/life-safety standards.
  • Experience performing inspection and testing documentation for Government or healthcare facilities.
  • Additional NICET certifications or manufacturer-specific certifications.

Physical Requirements

The position requires the ability to:

  • Lift and carry equipment and materials as required.
  • Work from ladders, lifts, and elevated work areas.
  • Work in mechanical rooms, electrical rooms, ceiling spaces, and other facility areas.
  • Stand, walk, bend, kneel, climb, and work for extended periods.
  • Work in varying environmental conditions.
  • Safely use hand tools, power tools, meters, and electronic test equipment.

Work Environment

The technician will work primarily at Moncrief Army Health Clinic at Fort Jackson, a military healthcare facility supporting Soldiers, Families, retirees, and other eligible beneficiaries.

Because the facility provides healthcare services and supports military readiness, the technician must maintain a professional appearance and conduct, exercise discretion while working in patient-care areas, and understand the importance of minimizing interruptions to clinical operations.

Safety & Compliance

All work shall be performed in accordance with applicable federal, state, local, Department of Defense, Fort Jackson, and facility requirements, including applicable:

  • NFPA standards
  • OSHA regulations
  • UFC requirements
  • EM 385-1-1
  • Manufacturer requirements
  • Fort Jackson installation policies and procedures
  • Facility-specific safety and infection-control requirements

Key Competencies

The ideal candidate will demonstrate:

  • Technical expertise in fire alarm systems
  • Strong troubleshooting and diagnostic ability
  • Attention to detail
  • Commitment to life-safety and code compliance
  • Professional communication
  • Dependability and punctuality
  • Ability to work independently
  • Ability to prioritize and manage multiple service requirements
  • Strong documentation skills
  • Commitment to customer service and mission support

Start Date

September 1, 2026

Candidates selected for the position should be prepared to complete all required onboarding, background/access requirements, and site-specific training before or in conjunction with the start of employment.

Frequently Asked Questions

Is the salary disclosed for the NICET II Fire Alarm Technician position at ho-chunk?
The salary for this NICET II Fire Alarm Technician role at ho-chunk is not publicly listed. Click "Apply Now" to learn more about the compensation package on their official careers page.
Where is the NICET II Fire Alarm Technician position at ho-chunk located?
This NICET II Fire Alarm Technician role at ho-chunk is based in Columbia, SC, US. The position is listed as on-site or hybrid. Check the full job description or apply directly to confirm the work arrangement.
Is the NICET II Fire Alarm Technician role at ho-chunk full-time or part-time?
This is listed as a FULL TIME position. It is posted as a NICET II Fire Alarm Technician role in the Government Contracts department at ho-chunk.
Which team or department does the NICET II Fire Alarm Technician at ho-chunk belong to?
This NICET II Fire Alarm Technician position is part of the Government Contracts department at ho-chunk. See the full job description for more information about the team structure and responsibilities.
How do I apply for the NICET II Fire Alarm Technician position at ho-chunk?
Click the "Apply Now" button on this page. You will be redirected to ho-chunk's official application portal hosted on icims where you can submit your application directly.
When was the NICET II Fire Alarm Technician job at ho-chunk posted?
This NICET II Fire Alarm Technician position at ho-chunk was posted on Aug 31, 2026. Apply as soon as possible — early applications are often reviewed first.
NICET II Fire Alarm Technician
ho-chunk
Apply for this role ↗

You'll be redirected to ho-chunk's official application page on icims.